summaryrefslogtreecommitdiff
path: root/drivers/thermal/Kconfig
blob: e7dfb563abae19155d847227c90c53d7a15f541f (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
#
# Generic thermal sysfs drivers configuration
#

menuconfig THERMAL
	tristate "Generic Thermal sysfs driver"
	help
	  Generic Thermal Sysfs driver offers a generic mechanism for
	  thermal management. Usually it's made up of one or more thermal
	  zone and cooling device.
	  Each thermal zone contains its own temperature, trip points,
	  cooling devices.
	  All platforms with ACPI thermal support can use this driver.
	  If you want this support, you should say Y or M here.

if THERMAL

config THERMAL_HWMON
	bool
	prompt "Expose thermal sensors as hwmon device"
	depends on HWMON=y || HWMON=THERMAL
	default y
	help
	  In case a sensor is registered with the thermal
	  framework, this option will also register it
	  as a hwmon. The sensor will then have the common
	  hwmon sysfs interface.

	  Say 'Y' here if you want all thermal sensors to
	  have hwmon sysfs interface too.

config THERMAL_OF
	bool
	prompt "APIs to parse thermal data out of device tree"
	depends on OF
	default y
	help
	  This options provides helpers to add the support to
	  read and parse thermal data definitions out of the
	  device tree blob.

	  Say 'Y' here if you need to build thermal infrastructure
	  based on device tree.

choice
	prompt "Default Thermal governor"
	default THERMAL_DEFAULT_GOV_STEP_WISE
	help
	  This option sets which thermal governor shall be loaded at
	  startup. If in doubt, select 'step_wise'.

config THERMAL_DEFAULT_GOV_STEP_WISE
	bool "step_wise"
	select THERMAL_GOV_STEP_WISE
	help
	  Use the step_wise governor as default. This throttles the
	  devices one step at a time.

config THERMAL_DEFAULT_GOV_FAIR_SHARE
	bool "fair_share"
	select THERMAL_GOV_FAIR_SHARE
	help
	  Use the fair_share governor as default. This throttles the
	  devices based on their 'contribution' to a zone. The
	  contribution should be provided through platform data.

config THERMAL_DEFAULT_GOV_PID
	bool
	prompt "pid_thermal_gov"
	select THERMAL_GOV_PID
	help
	  Use the PID thermal governor as default. This throttles the
	  devices based on output values of PID controller.

config THERMAL_DEFAULT_GOV_USER_SPACE
	bool "user_space"
	select THERMAL_GOV_USER_SPACE
	help
	  Select this if you want to let the user space manage the
	  platform thermals.

endchoice

config THERMAL_GOV_FAIR_SHARE
	bool "Fair-share thermal governor"
	help
	  Enable this to manage platform thermals using fair-share governor.

config THERMAL_GOV_STEP_WISE
	bool "Step_wise thermal governor"
	help
	  Enable this to manage platform thermals using a simple linear
	  governor.

config THERMAL_GOV_PID
	bool "PID thermal governor"
	help
	  This governor manages thermals based on output values of
	  PID controller.

config THERMAL_GOV_USER_SPACE
	bool "User_space thermal governor"
	help
	  Enable this to let the user space manage the platform thermals.

config CPU_THERMAL
	bool "generic cpu cooling support"
	depends on CPU_FREQ
	depends on THERMAL_OF
	help
	  This implements the generic cpu cooling mechanism through frequency
	  reduction. An ACPI version of this already exists
	  (drivers/acpi/processor_thermal.c).
	  This will be useful for platforms using the generic thermal interface
	  and not the ACPI interface.

	  If you want this support, you should say Y here.

config THERMAL_EMULATION
	bool "Thermal emulation mode support"
	help
	  Enable this option to make a emul_temp sysfs node in thermal zone
	  directory to support temperature emulation. With emulation sysfs node,
	  user can manually input temperature and test the different trip
	  threshold behaviour for simulation purpose.

	  WARNING: Be careful while enabling this option on production systems,
	  because userland can easily disable the thermal policy by simply
	  flooding this sysfs node with low temperature values.

config GENERIC_ADC_THERMAL
	tristate
	prompt "Generic ADC thermal sensor support using IIO framework"
	depends on THERMAL
	depends on IIO
	help
	  Enable support for the generic ADC thermal sensor driver
	  using IIO framework.

config SPEAR_THERMAL
	bool "SPEAr thermal sensor driver"
	depends on PLAT_SPEAR
	depends on OF
	help
	  Enable this to plug the SPEAr thermal sensor driver into the Linux
	  thermal framework.

config RCAR_THERMAL
	tristate "Renesas R-Car thermal driver"
	depends on ARCH_SHMOBILE
	help
	  Enable this to plug the R-Car thermal sensor driver into the Linux
	  thermal framework.

config KIRKWOOD_THERMAL
	tristate "Temperature sensor on Marvell Kirkwood SoCs"
	depends on ARCH_KIRKWOOD
	depends on OF
	help
	  Support for the Kirkwood thermal sensor driver into the Linux thermal
	  framework. Only kirkwood 88F6282 and 88F6283 have this sensor.

config EXYNOS_THERMAL
	tristate "Temperature sensor on Samsung EXYNOS"
	depends on (ARCH_EXYNOS4 || ARCH_EXYNOS5)
	depends on CPU_THERMAL
	help
	  If you say yes here you get support for TMU (Thermal Management
	  Unit) on SAMSUNG EXYNOS series of SoC.

config DOVE_THERMAL
	tristate "Temperature sensor on Marvell Dove SoCs"
	depends on ARCH_DOVE
	depends on OF
	help
	  Support for the Dove thermal sensor driver in the Linux thermal
	  framework.

config DB8500_THERMAL
	bool "DB8500 thermal management"
	depends on ARCH_U8500
	default y
	help
	  Adds DB8500 thermal management implementation according to the thermal
	  management framework. A thermal zone with several trip points will be
	  created. Cooling devices can be bound to the trip points to cool this
	  thermal zone if trip points reached.

config ARMADA_THERMAL
	tristate "Armada 370/XP thermal management"
	depends on ARCH_MVEBU
	depends on OF
	help
	  Enable this option if you want to have support for thermal management
	  controller present in Armada 370 and Armada XP SoC.

config DB8500_CPUFREQ_COOLING
	tristate "DB8500 cpufreq cooling"
	depends on ARCH_U8500
	depends on CPU_THERMAL
	default y
	help
	  Adds DB8500 cpufreq cooling devices, and these cooling devices can be
	  bound to thermal zone trip points. When a trip point reached, the
	  bound cpufreq cooling device turns active to set CPU frequency low to
	  cool down the CPU.

config INTEL_POWERCLAMP
	tristate "Intel PowerClamp idle injection driver"
	depends on THERMAL
	depends on X86
	depends on CPU_SUP_INTEL
	help
	  Enable this to enable Intel PowerClamp idle injection driver. This
	  enforce idle time which results in more package C-state residency. The
	  user interface is exposed via generic thermal framework.

config PWM_FAN
	bool "PWM Fan driver"
	depends on THERMAL
	help
	  Enables the fan driver that is controlled by pwm

config PALMAS_THERMAL
	tristate "TI Palmas Thermal driver"
	depends on MFD_PALMAS
	help
	 Palmas series pmic chip supports hot die interrupt configurable for 4
	 different critical temperature thresholds from which we can notify
	 thermal core to orderly power off the system.

config SENSORS_TMP006
	tristate "Skin Temperature Sensor"
	depends on I2C
	help
	 Say yes here if you wish to include the skin Temperature sensor.

	 To compile this driver as a module, choose M here: the
	 module will be called tmp006. If unsure, say N here.

endif